Temperature Monitoring Constraints
See Temperature Monitoring API
AR758x, AR759x platform restrictions:
The temperature monitoring feature using Legato APIs is partially applicable for AR758X and AR759X platforms. Only the below functions are available:
The other APIs managing the thresholds concept are not operational. Please contact Sierra Wireless support for a fully monitoring of the temperature another way.
For other platforms the temperature monitoring feature is available.
Two main sensors are supported. The dedicated string to request a sensor with le_temp_Request() function are "POWER_CONTROLLER" and "POWER_AMPLIFIER".
"POWER_AMPLIFIER" sensor
Two Thresholds can be set to notify the "POWER_AMPLIFIER" sensor state:
- "HI_CRITICAL_THRESHOLD"
- "HI_NORMAL_THRESHOLD"
These are the strings to use with the le_temp_SetThreshold() and le_temp_GetThreshold() functions.
Then, the "POWER_AMPLIFIER" sensor state will be notified with the following events (always a string format):
- "HI_CRITICAL_EVENT"
- "HI_WARNING_EVENT"
- "NORMAL_EVENT"
if the "POWER_AMPLIFIER" sensor temperature reaches the:
- "HI_CRITICAL_THRESHOLD" threshold, a "HI_CRITICAL_EVENT" event occurs.
- "HI_NORMAL_THRESHOLD" threshold but still lower than "HI_CRITICAL_THRESHOLD" threshold, a "HI_WARNING_EVENT" event occurs.
^ | --> "HI_CRITICAL_EVENT" | "HI_CRITICAL_THRESHOLD" | ^ --> "HI_WARNING_EVENT" | "HI_NORMAL_THRESHOLD" | ^ |
if the "POWER_AMPLIFIER" sensor temperature decreases below the:
- "HI_CRITICAL_THRESHOLD" - 3°C threshold but still higher than "HI_NORMAL_THRESHOLD" threshold, a "HI_WARNING_EVENT" event occurs.
- "HI_NORMAL_THRESHOLD" - 3°C threshold, a "NORMAL_EVENT" event occurs.
| v | "HI_CRITICAL_THRESHOLD" - 3°C | v --> "HI_WARNING_EVENT" | "HI_NORMAL_THRESHOLD" - 3°C | | --> "NORMAL_EVENT" v
- Warning
- A minimum gap of 2°C must be set between the thresholds.
"POWER_CONTROLLER" sensor
Four Thresholds can be set to notify the "POWER_CONTROLLER" sensor state:
- "HI_CRITICAL_THRESHOLD"
- "HI_NORMAL_THRESHOLD"
- "LO_NORMAL_THRESHOLD"
- "LO_CRITICAL_THRESHOLD"
These are the strings to use with the le_temp_SetThreshold() and le_temp_GetThreshold() functions.
Then, the "POWER_CONTROLLER" sensor state will be notified with the following events (always a string format):
- "HI_CRITICAL_EVENT"
- "HI_WARNING_EVENT"
- "NORMAL_EVENT"
- "LO_WARNING_EVENT"
- "LO_CRITICAL_EVENT"
if the "POWER_CONTROLLER" sensor temperature reaches the:
- "LO_CRITICAL_THRESHOLD" threshold, a "LO_WARNING_EVENT" event occurs.
- "LO_NORMAL_THRESHOLD" + 3°C threshold but still lower than "HI_NORMAL_THRESHOLD" threshold, a "NORMAL_EVENT" event occurs.
- "HI_NORMAL_THRESHOLD" threshold but still lower than "HI_CRITICAL_THRESHOLD" threshold, a "HI_WARNING_EVENT" event occurs
- "HI_CRITICAL_THRESHOLD" threshold, a "HI_CRITICAL_EVENT" event occurs.
^ | --> "HI_CRITICAL_EVENT" | "HI_CRITICAL_THRESHOLD" | ^ --> "HI_WARNING_EVENT" | "HI_NORMAL_THRESHOLD" | ^ --> "NORMAL_EVENT" | "LO_NORMAL_THRESHOLD" + 3°C | ^ --> "LO_WARNING_EVENT" | "LO_CRITICAL_THRESHOLD" | ^ |
if the "POWER_CONTROLLER" sensor temperature decreases below the:
- "HI_CRITICAL_THRESHOLD" threshold, a "HI_WARNING_EVENT" event occurs.
- "HI_NORMAL_THRESHOLD" - 3°C threshold but still higher than "LO_NORMAL_THRESHOLD" threshold, a "NORMAL_EVENT" event occurs.
- "LO_NORMAL_THRESHOLD" threshold but still higher than "LO_CRITICAL_THRESHOLD" threshold, a "LO_WARNING_EVENT" event occurs.
- "LO_CRITICAL_THRESHOLD" threshold, a "LO_CRITICAL_EVENT" event occurs.
| v | "HI_CRITICAL_THRESHOLD" | v --> "HI_WARNING_EVENT" | "HI_NORMAL_THRESHOLD" - 3°C | v --> "NORMAL_EVENT" | "LO_NORMAL_THRESHOLD" | v --> "LO_WARNING_EVENT" | "LO_CRITICAL_THRESHOLD" | | --> "LO_CRITICAL_EVENT" v
- Warning
- A minimum gap of 4°C must be set between "LO_NORMAL_THRESHOLD" and "HI_NORMAL_THRESHOLD".
- A minimum gap of 2°C must be set between other thresholds.
- Note
- Please refer to the Product Technical specification document of your platform for further details.
Copyright (C) Sierra Wireless Inc.