The cellular modem tool is used to control modem functions.
cm [SERVICES] [COMMANDS]
Available services are radio, sim and data.
cm radio
Get modem status
cm radio <on/off>
Enable/disable radio
cm radio rat <CDMA/GSM/UMTS/LTE>
Set radio access technology
After setting the radio access technology, you'll need to do a legato restart
before it's effective.
cm sim
Get sim status
cm sim enterpin <pin>
Enter pin code that's required before any mobile equipment functionality can be used.
cm sim changepin <oldpin> <newpin>
Change the PIN code of the SIM card.
cm sim lock <pin>
Lock SIM: enables SIM card security, will request for a PIN code when inserted.
cm sim unlock <pin>
Unlock SIM: disables SIM card security, won't request a PIN code when inserted (unsafe).
cm sim unblock <puk> <newpin>
Unblocks the SIM card. The SIM card is blocked after X unsuccessful attempts to enter the PIN.
cm sim storepin <pin>
Stores PIN. Whether security is enabled or not, the SIM card has a PIN code that must be entered for every operation. You can change the PIN code through
changepin
andunblock
.
cm data
Get info on profile in use
cm data profile <index>
Set profile in use
cm data apn <apn>
Set apn for profile in use
cm data pdp <pdp>
Set pdp type for profile in use
cm data auth <none/pap/chap> <username> <password>
Set authentication for profile in use
cm data connect <optional timeout (secs)>
Start a data connection
cm data list
List all the profiles
cm data watch
Monitor the data connection
To start a data connection, please ensure that your profile has been configured correctly. Also ensure your modem is registered to the network. To verify, use cm radio
and check Status
.
If you specify a time-out timer when starting a data connection, it will try to start a data connection until the timer expires.
When starting a data connection, currently it only uses profile 1. Any configuration set for other profiles can't be used to start a data connection through the cm tool.
If you're upgrading from Legato Beta 14.04, data connection operation will be slightly different. Once you have a data connection started successfully, the process will continue running.
To stop the session, do one of these:
cm data connect
as usual and if you want to release the data connection, simply press CTRL+C.cm data connect &
(background) and if you want to release the data connection, kill the process (kill <pid>
).Copyright (C) Sierra Wireless, Inc. 2014. All rights reserved. Use of this work is subject to license.